BELT CONVEYER

Idle Power:P1 =9.8μωνl〔W〕
Horizontal Power: P2=μQ/367〔W〕
Vertical Power:P3=±QH/367〔W〕
                                                    
 Pg =(P1+P2+P3)100/n〔W〕
 Pg: Power required〔W〕
 l:Length of conveyor(m)
    (distance between sfafts)
 ω:Weight of belt unit length(kg/m)
 μ:Friction Coefficient
 v:Belt speed(m/sec)
 Q:Conveying capacity(kg/h)
 n:Efficiency(%)
 H:Height difference at two ends of tilting conveyer(m)

Note:above are basic formulas on regular basis. In the practical use select the motor according to safety of design, chage of power supply, practical starting velocity as well as influence of loading cpacity.